The aim of the review by Bornstein et al was to identify, review, analyze, and summarize available evidence on the use of CBCT imaging in pre- and postoperative dental implant therapy with regard to:
With respect to CBCT imaging in dental implant therapy and respective use guidelines, specific indications and contraindications for use, and the associated relative radiation dose risk, the following statements can be made:
- Current clinical practice guidelines for CBCT use in implant dentistry provide recommendations that are consensus-based or derived from non-standardized methodological approaches.
- Published indications for CBCT use in implant dentistry vary from preoperative analysis to postoperative evaluation, including complications. However, a clinically significant benefit for CBCT imaging over conventional two-dimensional methods resulting in treatment plan alteration, improved implant success, survival rates, and reduced complications has not been reported to date.
- CBCT imaging exhibits a significantly lower radiation dose risk than conventional CT, but higher than that of two-dimensional radiographic imaging. Different CBCT devices deliver a wide range of radiation doses. Substantial dose reduction can be achieved by using appropriate exposure parameters and reducing the field of view (FOV) to the actual region of interest (ROI).